Place of Origin: | China |
Brand Name: | zealchon |
Certification: | ISO |
Model Number: | A009 |
Minimum Order Quantity: | 1set |
---|---|
Price: | $1500 |
Packaging Details: | wooden box |
Delivery Time: | 7days |
Payment Terms: | L/C, Western Union, T/T |
Supply Ability: | 100sets/month |
, The Working Power: | AC 220V ± 10%, 50Hz. | Heating Device: | Heating Power From 0 ~ 600W Continuously Adjustable. |
---|---|---|---|
The Sample Heating Rate: | 1 ~ 12 ℃ / Min, Controllable Adjustable | Electric Mixing Device: | 90 ~ 120 R / Min, For Test Step A. |
Test Oil Volume Groove Depth: | 33.9 ~ 34.3 Mm. |
Petroleum products flash point and ignition tester YSYD-261,flash point tester
Scope
The instrument is in accordance with the ASTM D93, GB / T 261 "Determination of the flash point of Pensky -
Martin closed cup method" under the requirements of design and manufacturing
Features
1, The design of the instrument in full compliance with GB / T261 standard requirements.
2, Heating power continuous, stepless adjustable, the size of power by the voltmeter intuitive display, advanced
temperature control, and reasonable.
3, Compact design, stainless steel table top appearance, easy to remove oil.
4, Easy to operate, the test results are accurate, a number of measurement units selected for the closed-mouth flash
point detection equipment.
Technical Parameters
1, The working power:AC 220V ± 10%, 50Hz.
2, Heating device: heating power from 0 ~ 600W continuously adjustable.
3, The sample heating rate: 1 ~ 12 ℃ / min, controllable adjustable.
4, Electric mixing device: 90 ~ 120 r / min, for test step A.
250 ± 10 r / min, applicable to test step B.
6, The standard oil cup:
Dameter: 50.7 ~ 50.8 mm.
Depth: 55.7 ~ 56.0 mm.
Test oil volume groove depth: 33.9 ~ 34.3 mm.
Test oil capacity: about 70 ml.
7, The fire device: ignition source: gas (or other civilian gas, the same below). caliber of the pilot: 0.8 mm.
8, The thermometer: rod-type mercury thermometer, in line with GB / T 261-2008 standards.
Temperature range -5 ~ 110 ℃, sub-degree 0.5 ℃.
Temperature range 20 ~ 150 ℃, sub-degree 1.0 ℃.
Temperature range 90 ~ 370 ℃, sub-2 ℃.
9, The ambient temperature: ≤ 35 ℃.
10, Telative humidity: ≤ 85%.
11, The machine power consumption: not more than 650W.
Service:
1. Warranty 1 year of replacement and return.
2, Providing factory visit and study, technical training
3, 24-hour technical support by e-mail or phone
4, Providing laboratory construction program design guidelines
5, Providing product design and OEM service