Sales & Support: Request A Quote
Home Productsdrilling fluid instrument

A009 Manual Closed cup flash point tester

A009 Manual Closed cup flash point tester

A009 Manual Closed cup flash point tester

Product Details:

Place of Origin: China
Brand Name: zealchon
Certification: ISO
Model Number: A009

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: $1500
Packaging Details: wooden box
Delivery Time: 7days
Payment Terms: L/C, Western Union, T/T
Supply Ability: 100sets/month
Contact Now
Detailed Product Description
, The Working Power: AC 220V ± 10%, 50Hz. Heating Device: Heating Power From 0 ~ 600W Continuously Adjustable.
The Sample Heating Rate: 1 ~ 12 ℃ / Min, Controllable Adjustable Electric Mixing Device: 90 ~ 120 R / Min, For Test Step A.
Test Oil Volume Groove Depth: 33.9 ~ 34.3 Mm.

Product Description

A009 Manual Closed cup flash point tester

 

 

Petroleum products flash point and ignition tester YSYD-261,flash point tester

 

Scope


The instrument is in accordance with the ASTM D93, GB / T 261 "Determination of the flash point of Pensky -
Martin closed cup method" under the requirements of design and manufacturing
Features
1, The design of the instrument in full compliance with GB / T261 standard requirements.
2, Heating power continuous, stepless adjustable, the size of power by the voltmeter intuitive display, advanced
temperature control, and reasonable.
3, Compact design, stainless steel table top appearance, easy to remove oil.
4, Easy to operate, the test results are accurate, a number of measurement units selected for the closed-mouth flash
point detection equipment.


Technical Parameters


1, The working power:AC 220V ± 10%, 50Hz.
2, Heating device: heating power from 0 ~ 600W continuously adjustable.
3, The sample heating rate: 1 ~ 12 ℃ / min, controllable adjustable.
4, Electric mixing device: 90 ~ 120 r / min, for test step A.
250 ± 10 r / min, applicable to test step B.
6, The standard oil cup:

 

Dameter: 50.7 ~ 50.8 mm.

Depth: 55.7 ~ 56.0 mm.
Test oil volume groove depth: 33.9 ~ 34.3 mm.
Test oil capacity: about 70 ml.


7, The fire device: ignition source: gas (or other civilian gas, the same below). caliber of the pilot: 0.8 mm.
8, The thermometer: rod-type mercury thermometer, in line with GB / T 261-2008 standards.
Temperature range -5 ~ 110 ℃, sub-degree 0.5 ℃.
Temperature range 20 ~ 150 ℃, sub-degree 1.0 ℃.
Temperature range 90 ~ 370 ℃, sub-2 ℃.
9, The ambient temperature: ≤ 35 ℃.
10, Telative humidity: ≤ 85%.
11, The machine power consumption: not more than 650W.

 

 

 

Detailed Images

 

 

Lab Display

 

Trade Shows

 

 

Packing and Shipping

 

 

 

After-Sales Service

 

 

 

Service:

 

 

 

1. Warranty 1 year of replacement and return.

 

 

2, Providing factory visit and study, technical training

 

 

3, 24-hour technical support by e-mail or phone

 

 

4, Providing laboratory construction program design guidelines

 

 

5, Providing product design and OEM service

 

 

 

Contact Us

 

 

 
 
 

 

Contact Details
Xian Zealchon Electronic Technology Co., Ltd.

Contact Person: Mr. Elieen Liang

Tel: 86--15091779716

Send your inquiry directly to us (0 / 3000)